Описание

  • Read head with guard locking without guard lock monitoring
  • Locking force 650 N
  • Without remanence
  • Up to category 4 according to EN ISO 13849-1
  • Two safety screws M5x16 included
Without remanenceRead heads without remanence are de-magnetized when the solenoid is switched off. For this purpose the operating voltage UB must always be applied. Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off. Dimension drawing
Material
Read head Plastic (PPS)
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Weight
Net 0,3 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Switching frequency
Read head See operating instructions for the related evaluation unit
Solenoid max.2 Hz
Connection
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
X3, read head Plug connector M8x1, 3-pin male (with snap-action / screw terminal)
Cable length max.25 m
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 650 N
Adhesive force
due to remanence 0,5 N
Electrical connection ratings
Operating voltage DC
UB 24 V DC -15% ... 10%
UCM 24 V DC -15% ... 10%
Current consumption
On UB at UCM?0V 12 mA
On UB at UCM?24V 100 mA
On UCM at 24V 15 mA
Power consumption 2,8 W
Solenoid duty cycle 100 %
Work area
Switching hysteresis 0,7 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao min.2 mm
Center offset -2,5 ... +2,5 mm
''